Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rio de Janeiro; s.n; 2010. 68 p. ilus, graf, tab.
Tese em Português | LILACS, BBO - Odontologia | ID: lil-673673

RESUMO

Durante o tratamento ortodôntico, a resposta inicial dos tecidos periodontais ao estímulo mecânico envolve várias alterações estruturais e bioquímicas que permitem a movimentação do dente. As metaloproteinases da matriz (MMPs) parecem desempenhar um papel importante na manutenção da integridade funcional da matriz extracelular periodontal. O objetivo do presente estudo foi avaliar, em diferentes intervalos de tempo, os níveis de metaloproteinases da matriz -1, -2, -3, -7, -8, -12 e -13 no fluido gengival (FG) de caninos superiores submetidos ao movimento de distalização e testar a hipótese de possíveis alterações nos níveis destas MMPs com o emprego de forças ortodônticas. Amostras de FG foram obtidas de dezesseis pacientes ortodônticos saudáveis (nove do sexo masculino e sete do sexo feminino, com idades entre 13 e 27 anos, média de idade 17,7 anos) que possuíam indicação de exodontias dos primeiros pré-molares superiores e tiveram os caninos distalizados como parte da terapia ortodôntica. Um dos caninos superiores foi distalizado ortodonticamente, sendo considerado dente teste. O canino contralateral não foi submetido a nenhuma força, no entanto foi incluído na aparatologia ortodôntica e utilizado como controle. A coleta de FG foi realizada nos sítios mesial (tensão) e distal (pressão) dos dentes testes e controles 7 dias antes da montagem da aparatologia ortodôntica, imediatamennte após a aplicação da força ortodôntica, e após 1 h, 24 h, e 7, 14 e 21 dias, respectivamente denominados -7d, 0h, 1h, 24h, 7d, 14d e 21d. A arcada superior de cada paciente foi dividida em um lado teste e um lado controle. Os resultados mostraram que foram encontradas diferenças significativas no volume do FG apenas nos intervalos de tempo entre -7d e 0h nos lados controle-pressão (CP), teste-tensão (TT) e teste-pressão (TP). Em TP foi observado ainda aumento do volume entre os tempos 0h e 14d. Foi possível detectar no FG as MMPs estudadas...


During orthodontic treatment, the initial response of periodontal tissues to mechanical stress involves several structural and biochemical changes that allow the tooth movement. The matrix metalloproteinases (MMPs) seem to play an important role in maintaining the functional integrity of periodontal extracellular matrix. The aim of this study was to evaluate, in different periods, the levels of matrix metalloproteinases -1, -2, -3, -7, -8, -12 and -13 in gingival crevicular fluid (GCF) of the superior caninessubmitted to distalization movement and test the hypothesis of possible changes in these MMP’s levels with the use of orthodontic forces. GCF samples were obtained from sixteen healthy orthodontic patients (nine males and seven females with ages ranging between 13 and 27 years, mean age 17.7 years) who had indication of first superior bicuspids extraction with cuspids distalization as part of orthodontic treatment. One maxillary canine was subjected to a distalizing force, and considered as the test tooth. The contralateral canine, which was not subjected to any force but was included in an orthodontic appliance, was used as a control. GCF sampling was performed at both mesial (tension) and distal (pressure) sites of the controls and tests teeth 7 days before applying the orthodontic appliance, immediately before applying the orthodontic force, and after 1 h, 24 h, and 7, 14 and 21 days, respectively called -7d, 0h, 1h, 24h, 7d, 14d and 21 d. The results showed significant differences in the GCF volume only in time intervals of 0h-7d on control-pressure (CP), test-tension (TT) and test-pressure (TP) sides. In TP side was observed an increase in volume between the time 0h and 14d. It was possible to detect in GCF all MMPs studied on control/test sides and pressure/tension sides at all periods. Fluctuations in levels of MMPs showed few significant changes in different periods on the sides control/test and pressure/tension. The differences...


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto Jovem , Líquido do Sulco Gengival , Metaloproteinases da Matriz , Técnicas de Movimentação Dentária , Dente Canino , Periodonto
2.
Rio de Janeiro; s.n; 2010. 68 p. ilus, graf, tab.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-866118

RESUMO

Durante o tratamento ortodôntico, a resposta inicial dos tecidos periodontais ao estímulo mecânico envolve várias alterações estruturais e bioquímicas que permitem a movimentação do dente. As metaloproteinases da matriz (MMPs) parecem desempenhar um papel importante na manutenção da integridade funcional da matriz extracelular periodontal. O objetivo do presente estudo foi avaliar, em diferentes intervalos de tempo, os níveis de metaloproteinases da matriz -1, -2, -3, -7, -8, -12 e -13 no fluido gengival (FG) de caninos superiores submetidos ao movimento de distalização e testar a hipótese de possíveis alterações nos níveis destas MMPs com o emprego de forças ortodônticas. Amostras de FG foram obtidas de dezesseis pacientes ortodônticos saudáveis (nove do sexo masculino e sete do sexo feminino, com idades entre 13 e 27 anos, média de idade 17,7 anos) que possuíam indicação de exodontias dos primeiros pré-molares superiores e tiveram os caninos distalizados como parte da terapia ortodôntica. Um dos caninos superiores foi distalizado ortodonticamente, sendo considerado dente teste. O canino contralateral não foi submetido a nenhuma força, no entanto foi incluído na aparatologia ortodôntica e utilizado como controle. A coleta de FG foi realizada nos sítios mesial (tensão) e distal (pressão) dos dentes testes e controles 7 dias antes da montagem da aparatologia ortodôntica, imediatamennte após a aplicação da força ortodôntica, e após 1 h, 24 h, e 7, 14 e 21 dias, respectivamente denominados -7d, 0h, 1h, 24h, 7d, 14d e 21d. A arcada superior de cada paciente foi dividida em um lado teste e um lado controle. Os resultados mostraram que foram encontradas diferenças significativas no volume do FG apenas nos intervalos de tempo entre -7d e 0h nos lados controle-pressão (CP), teste-tensão (TT) e teste-pressão (TP). Em TP foi observado ainda aumento do volume entre os tempos 0h e 14d. Foi possível detectar no FG as MMPs estudadas ...


During orthodontic treatment, the initial response of periodontal tissues to mechanical stress involves several structural and biochemical changes that allow the tooth movement. The matrix metalloproteinases (MMPs) seem to play an important role in maintaining the functional integrity of periodontal extracellular matrix. The aim of this study was to evaluate, in different periods, the levels of matrix metalloproteinases -1, -2, -3, -7, -8, -12 and -13 in gingival crevicular fluid (GCF) of the superior caninessubmitted to distalization movement and test the hypothesis of possible changes in these MMP’s levels with the use of orthodontic forces. GCF samples were obtained from sixteen healthy orthodontic patients (nine males and seven females with ages ranging between 13 and 27 years, mean age 17.7 years) who had indication of first superior bicuspids extraction with cuspids distalization as part of orthodontic treatment. One maxillary canine was subjected to a distalizing force, and considered as the test tooth. The contralateral canine, which was not subjected to any force but was included in an orthodontic appliance, was used as a control. GCF sampling was performed at both mesial (tension) and distal (pressure) sites of the controls and tests teeth 7 days before applying the orthodontic appliance, immediately before applying the orthodontic force, and after 1 h, 24 h, and 7, 14 and 21 days, respectively called -7d, 0h, 1h, 24h, 7d, 14d and 21 d. The results showed significant differences in the GCF volume only in time intervals of 0h-7d on control-pressure (CP), test-tension (TT) and test-pressure (TP) sides. In TP side was observed an increase in volume between the time 0h and 14d. It was possible to detect in GCF all MMPs studied on control/test sides and pressure/tension sides at all periods. Fluctuations in levels of MMPs showed few significant changes in different periods on the sides control/test and pressure/tension. The differences ...


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto Jovem , Adulto , Líquido do Sulco Gengival , Metaloproteinases da Matriz , Técnicas de Movimentação Dentária , Dente Canino , Periodonto
3.
Rio de Janeiro; s.n; 2007. 96 p. ilus, tab, graf.
Tese em Português | BBO - Odontologia | ID: biblio-865340

RESUMO

O desenvolvimento de fios ortodônticos que associem a vantagem estética com as necessidades biomecânicas tem sido um dos objetivos na Ortodontia. A maioria dos fios comercializados com finalidade estética são compostos por níquel-titânio (NiTi) com cobertura a base de teflon ou resina epoxídica. O objetivo deste trabalho foi avaliar, através de ensaios de tração, propriedades mecânicas dos fios ortodônticos estéticos, em relação aos de NiTi superelásticos tradicionais. Foram utilizados 36 fios ortodônticos de NiTi superelásticos, sendo 18 estéticos e 18 sem cobertura estética, de calibre 0,018”, das marcas TP Orthodontics, GAC e Masel. Os três exemplares de cada grupo foram alongados até a ruptura, com velocidade de ensaio de 1 milímetro de estiramento por minuto, a fim de se obter os patamares constantes de ativação dos fios. Os ensaios foram realizados a uma temperatura de 37°C, utilizando-se a máquina universal de ensaios Emic DL 10000 de 10 toneladas de capacidade, sendo utilizada uma célula de carga de 50 N (50 quilogramas). Os dados foram analisados estatisticamente aplicando-se a análise de variância (ANOVA), seguido pelo teste de Bonferroni. Os resultados mostraram que, de maneira geral, os fios não recobertos possuem cargas máximas de ruptura e cargas para atingir o patamar de ativação mais elevadas que os estéticos (p≤ 0,01), com exceção dos fios não recobertos da marca Masel que apresentam semelhança estatística com os estéticos da TP. O mesmo acontece com as cargas no início, em 2% e 4% de deformação nos patamares de ativação e desativação. Os fios estéticos apresentaram, nos testes de ruptura, extensão de patamares de ativação maiores (p≤ 0,01), sendo o mesmo observado nos testes de ativação e desativação com extensão dos patamares de carregamento e descarregamento mais elevados...


The development of orthodontic wires that offer esthetic advantage with biomechanical necessities has been one of the aims of Orthodontics. Most of the wires with esthetic purpose are made of nickel-titanium (NiTi) with Teflon or epoxy-resin coating. This study’s aims were to evaluate, through stress-strain tests, mechanical properties of the esthetic orthodontic wires, comparing them to the traditional NiTi superelastic ones. 36 superelastic NiTi orthodontic wires – 18 esthetic and 18 with no esthetic coating – with a 0,018” caliber, from the brands TP Orthodontics, GAC e Masel were used. The three samples of each group were extended till fracture, with a testing speed of 1 millimeter of extending per minute, with the purpose of obtaining constant plateaus of wire activation. The tests were made on a temperature of 37ºC, using the universal testing EMIC DL 10000 with 10 tons of capacity, and a 50N (50 kilograms) charging cell. The datas were analyzed statistically using the analysis of variance (ANOVA), followed by the Bonferroni test. The results proved that, in general, the uncoated wires have higher maximum fracture resistance charges and more elevated charges to reach loading plateau (p≤ 0,01) than the esthetic ones, with the exception of the uncoated Masel wires, which were statistically similar to esthetic TP wires. The same was observed with the charges in the beginning, with a 2% and 4% deforming on the loading and unloading plateaus. The esthetic wires presented, on the rupture tests, higher extension of loading plateaus than the esthetic ones (p≤ 0,01). The same was observed on the activation and deactivation tests with a higher extension of the loading and unloading plateaus. In the area under the activation curves no statistically relevant difference was observed on the valuated wires with the exception of the uncoated wires from TP, which showed more elevated values...(AU)


Assuntos
Fios Ortodônticos , Ortodontia , Fenômenos Biomecânicos , Estética Dentária , Fenômenos Físicos , Resistência à Tração
4.
Rev. Clín. Ortod. Dent. Press ; 5(4): 69-74, ago.-set. 2006. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-519764

RESUMO

Desde o início da década de 80, quando foram identificados os primeiros casos de AIDS e descobriu-se que a doença poderia ser transmitida em consultórios odontológicos, os profissionais da área vêm mudando radicalmente suas atitudes em relaçao ao controle de infecções. No entanto, é possível constatar que, nos dias atuais, a frequência de utilização das medidas é baixa, se comparada aos dentistas de outras especialidades. Principalmente no que diz respeito à proteção ocular, o descuido é ainda maior, fato que tem levado a sérios danos oculares e à transmissão de infecções, seguidos, muitas vezes, de processos na justiça. Esse artigo pretende ressaltar a importância do uso de protetores oculares por toda a equipe odontológica e pacientes durante o atendimento ortodôntico, com o intuito de prevenir acidentes desagradáveis e possíveis ações judiciais.


Assuntos
Consultórios Odontológicos , Equipamentos de Proteção , Processo Legal , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Transmissão de Doença Infecciosa do Profissional para o Paciente/prevenção & controle , Traumatismos Oculares/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...